Insert the gauge "0.40" of the doctor sleeve
jig into the gap between the developer
sleeve and doctor blade. Confirm that the jig
moves smoothly to the front and rear side,
and the gauge "0.50" cannot be inserted into
the gap.
(8)
Confirm that the side seals are attached on
the toner scattering prevention sheet.