Update Procedure - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

11.2.3

Update procedure

Important:
The file system of USB media should be formatted in the FAT or FAT32 format. Be careful since
the devices formatted in NTFS or other format will not be able to be operated. The file system
can be confirmed on the device properties in applications such as Explorer of Windows.
Never shut down the equipment during the update. Firmware data and the following option data
(if installed) could be damaged and may not be able to be operated properly.
-
Data Overwrite Enabler (GP-1070)
-
Meta Scan Enabler (GS-1010)
-
External Interface Enabler (GS-1020)
-
IPSec Enabler (GP-1080)
-
Unicode Font Enabler (GS-1007)
Important:
The firmware to be overwritten by this update are as follows.
Master data (HD Data)
System Firmware (OS data)
Engine firmware
Scanner firmware
RADF firmware
Finisher firmware
Saddle stitcher firmware
Hole punch unit firmware
*1: MJ-1107/1108
[A] Update procedure
(1)
Connect the USB media to the PC and write the model specific folder in which the data file is
stored.
Store the data file for updating in the model specific folder.
(2)
Press the [ON/OFF] button on the control panel to shut down the equipment.
(3)
Connect the USB media [1] to the USB port [2] on the right upper cover.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO206L/256/306/356/
456/506
*2: MJ-1108
*3: MJ-6104
[2]
Fig.11-13
11 - 15