3.7.4

Hibernation function

A hibernation function is embedded in this equipment. This function allows the equipment to store the
last status of the system in the HDD immediately before the power is turned OFF, and to restart from
this stored status at the next boot-up. The equipment starts up in the specified time described in the
warmup time after the execution of the 2nd hibernation when the power is turned OFF and then back
ON correctly. *
For warming-up time, refer to  P. 2-1 "2.1.1 General"
It is recommended to shut down the equipment while pressing the [ACCESS] button and the [POWER]
button simultaneously before maintenance. However, warming-up takes longer when the equipment
boots up next time since no hibernation is executed. The equipment therefore boots up in the
initialization status. "Checking" is displayed on the LCD screen when the equipment boots up normally
(without hibernation), and "Checking" is not displayed when hibernation is executed.
If hibernation is not performed when the power is turned OFF or the equipment boots up immediately
after the settings, warming-up takes longer. It differs depending on the usage conditions; warming-up
will take approx. 30 to 150 sec, though it takes approx. 20 sec. if hibernation is performed (normal
situation).
The following are the conditions which necessitate a longer warming-up time.
Rebooting from TopAccess
First booting after power interruption
First booting after a self-diagnosis code is changed in the Service UI
First booting after the power is turned OFF with the main power switch during the super sleep mode
Installing options or finishers
First booting after an option or a finisher is removed
During toner supply
Operating while "READY (WARMING UP)" is still on the control panel
First booting after the [ACCESS] and [POWER] buttons are pressed and held until the power is shut
down
First booting after the power is turned OFF in a procedure other than the correct one described in
the Quick Start Guide
* How to turn the power OFF correctly
Press the [POWER] button on the control panel to shut down the equipment. Be sure to check that the
ON/OFF lamp (green) has stopped blinking and the touch panel screen and the lamp (green) have
gone off. Then turn the power OFF with the main power switch.