[Ea40] Cover Open Detection Error; [Ea50] Stapling Jam - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

[EA40] Cover open detection error

MJ-1032
Probable cause
Sub-path opening/closing
sensor (S12) abnormality
Front cover switch (SW1)
abnormality
Faulty cables and connectors
Finisher control PC board
(FIN) abnormality

[EA50] Stapling jam

Classification
Paper jam in finisher section
MJ-1101/1107
Check item
Finisher
Parts to be replaced
Finisher controller PC board
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
Checking and measures
Measure the voltage on TP12 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when
not shielded and within the range of 3.3V±5% when shielded. If the
voltage does not fall within the range mentioned, replace the
sensor.
Measure the voltage on TP77 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when
the switch is ON and within the range of 3.3V ± 5% when OFF. If the
voltage does not fall within the range mentioned, replace the switch.
Check if the electrical continuity between the connector terminals is normal.
If electricity is not conducted, replace the connector. (Finisher control PC
board (FIN): CN10, CN13)
If the error still occurs after replacing the switches, sensor and connector,
exchange the finisher control PC board (FIN).
Error content
Stapling jam
Check if there is any paper in the finisher or on the transport
path of the equipment or on the finishing tray. Remove it if there
is.
Is the jam cleared by taking off the staple cartridge from the
finisher and removing the staple sheet slid from the staple case?
Check if the actuator of the stapler interference sensor (S11)
moves smoothly.
Check if the connector CN2 on the finisher controller PC board is
disconnected from the stapler or the harnesses are open
circuited. Correct if any.
Check the harnesses in the stapler are disconnected or open
circuited. Correct if any.
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
8 - 101
Measures
Remark