Toshiba e-STUDIO206L Service Manual page 383

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

(5)
After a short time, the value B becomes stable and the display changes as follows.
(6)
Check if the value B is within the range of 234 to 246 (the output voltage range of the auto-toner
sensor is 2.34 V to 2.46 V).
(7)
If the value B is not within the range of 234 to 246, press the Up or Down button to adjust the
value manually.
Notes:
The relation between the button and the values A and B is as follows.
Button to be
pressed
Up
Down
(8)
Press the [OK] or [INTERRUPT] button.
The drum, developer unit, etc. are stopped and the following is displayed.
[INTERRUPT]
(9)
Turn the power OFF.
(10) Install the toner cartridge.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
B
240%
2000
ADJUSTMENT MODE
128
Fig.6-5
Value A
Increased
Decreased
100%
[OK]
or
TEST MODE
Fig.6-6
6 - 3
A3
150
A
Value B
Increased
Decreased
A3
A
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
SETTING / ADJUSTMENT