Press the [Button1] to adjust the alignment position.
Every time the [Button1] is pressed, the alignment plate shifts 1 step (0.419 mm/step) toward the
"+ "direction. (The gap between the alignment plates becomes narrower.)
Adjustment range is from -5 to +5 steps.
If the [Button1] is pressed when the alignment position is at the "+5 step", the plate will return to
the home position and then moves to the position of "-5 step".
(6)
Place the adjustment sheet [1] on the process tray and adjust the position to make the gap
between paper and the alignment plate [2] "0".
Then setting is performed at a value that is one smaller than the adjustment value.
Remarks:
Use an adjustment sheet [1] made of plastic resin which is light and accurate in measurement
(e.g. OHP film).
To reduce frictional resistance with the vertical alignment roller [3] on the process tray, place a
sheet of B5 paper [4] beneath the adjustment sheet [1] on the vertical alignment roller [3].
Confirm the gap between paper and the alignment plate [2] by moving the adjustment sheet
[1] forward and backward to reduce affect by backlash of the gear of the side alignment plate.