Pm Display Contents; Clearing Counter - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

7.2.3

PM display contents

When the counter value exceeds the setting value, the equipment notifies you of when the
maintenance time has come by displaying the message "Time for periodic maintenance ****" on the
control panel LCD. "****" in the message is a 4-digit hexadecimal number code. This number is
allocated in the following manner, therefore the parts needing maintenance can be identified.
PM parts of the process unit (K)
PM parts of the developer material (K)
Parts other than the PM parts of the process unit
If multiple parts have reached the maintenance time, the sum of the corresponding code values listed
above is displayed in hexadecimal numbers.
For example, if the peripheral parts of the process units (K) and developer material (K) reach the
maintenance time, the 4-digit hexadecimal number code will be "0188" in hexadecimal numbers:
0008+0080+0100=0188.
7.2.4

Clearing counter

The counter indicating "current number of prints and driving time" used for the PM display function is
reset by entering "0" in it or clearing it in the PM support mode.
Notes:
Even if "0" is entered in the PM management setting value of the setting mode (08), the
corresponding counter for the PM display is not reset. Be sure to clear the counter in the PM
support mode when the maintenance is finished.
The reset condition of each counter is as follows:
08-6194: Current value of PM counter [process unit (K)]
08-6195: Current value of PM time counter [process unit (K)]
When the current value of "CLEANER/DRUM" on the main screen or "DRUM" on the sub-screen in
the PM support mode is cleared, the counter is reset.
08-5568: Current value of PM time counter [developer material (K)]
08-5569: Current value of PM time counter [developer material (K)]
When the current value of "DEVELOPER" on the main screen or "DEVELOPER" on the sub-screen
in the PM support mode is cleared, the counter is reset.
08-5576: Current value of PM counter [parts other than the PM parts of the process unit]
08-5577: Current value of PM time counter [parts other than the PM parts of the process unit]
08-6225: Number of output pages (Thick paper 1)
08-6226: Number of output pages (Thick paper 2)
08-6227: Number of output pages (Thick paper 3)
08-6228: Number of output pages (OHP film)
08-6244: Counter for tab paper
08-6247: Counter for envelope
When the current value of "FUSER" on the main screen or "FUSER ROLLER" on the sub screen in
the PM support mode is cleared, the counter is reset.
Notes:
The following counters are cleared by executing the EPU replacement mode.
08-6194: Current value of PM counter [process unit (K)]
08-6195: Current value of PM time counter [process unit (K)]
08-5568: Current value of PM counter [developer material (K)]
08-5569: Current value of PM time counter [developer material (K)]
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
: 0008
: 0080
: 0100
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
7 - 3
PREVENTIVE MAINTENANCE (PM)
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents