Chapter 18: Installing the SRX5400 Services Gateway Without a Mechanical Lift
WARNING:
To prevent injury, keep your back straight and lift with your
legs, not your back. Avoid twisting your body as you lift. Balance the load
evenly and be sure that your footing is solid.
Slide the services gateway onto the mounting shelf until the mounting brackets contact
4.
the rack rails. The shelf ensures that the holes in the mounting brackets of the chassis
align with the holes in the rack rails.
Install a mounting screw into each of the open mounting holes aligned with the rack,
5.
starting from the bottom.
Visually inspect the alignment of the services gateway. If the services gateway is
6.
installed properly in the rack, all the mounting screws on one side of the rack should
be aligned with the mounting screws on the opposite side and the services gateway
should be level.

Figure 68: Installing the Services Gateway in the Rack

NOTE:
This illustration depicts the services gateway being installed in an
open-frame rack.
Overview of Installing the SRX5400 Services Gateway Without a Mechanical Lift on
page 147
Tools Required to Install the SRX5400 Services Gateway Without a Mechanical Lift
on page 148
153