CHAPTER 10

Grounding Specifications

SRX5400 Services Gateway Chassis Grounding Point Specifications

Copyright © 2017, Juniper Networks, Inc.
SRX5400 Services Gateway Chassis Grounding Point Specifications on page 107
SRX5400 Services Gateway Grounding-Cable Lug Specification on page 108
SRX5400 Services Gateway Grounding-Cable Specification on page 109
WARNING:
To meet safety and electromagnetic interference (EMI)
requirements and to ensure proper operation, you must properly ground the
services gateway chassis before connecting power. See
SRX5400 Services Gateway" on page 180
CAUTION:
Before services gateway installation begins, a licensed electrician
must attach cable lugs to the grounding and power cables that you supply.
A cable with an incorrectly attached lug can damage the services gateway.
The services gateway chassis has one grounding point at the upper right corner of the
back panel. The grounding point consists of two threaded holes spaced 0.625-in.
(15.86-mm) apart
(Figure 56 on page
screws. The accessory box shipped with the services gateway includes the cable lug that
attaches to the grounding cable and two UNC 1/4–20 screws used to secure the grounding
cable to the services gateway grounding point.
for instructions.
108). The grounding point holes fit UNC 1/4–20