Installing the SRX5400 Services Gateway Chassis in the Rack Manually

152

Figure 67: Removing a Card (MPC Shown, Other Card Types Similar)

Installing the SRX5400 Services Gateway Chassis in the Rack Manually on page 152
Reinstalling Components in the SRX5400 Services Gateway Chassis After Installing
It Without a Lift on page 154
To install the device in the rack (see
CAUTION:
If you are installing more than one services gateway in a rack,
install the lowest one first. Installing a services gateway in an upper position
in a rack or cabinet requires a lift.
CAUTION:
Before front mounting the services gateway in a rack, have a
qualified technician verify that the rack is strong enough to support the
services gateway's weight and is adequately supported at the installation
site.
CAUTION:
Lifting the chassis and mounting it in a rack requires two people.
The empty chassis weighs approximately 65 lb (29 kg).
Ensure that the rack is in its permanent location and is secured to the building. Ensure
1.
that the installation site allows adequate clearance for both airflow and maintenance.
Position the services gateway in front of the rack or cabinet, centering it in front of the
2.
mounting shelf. Use a pallet jack if one is available.
With one person on each side, hold onto the bottom of the chassis and carefully lift
3.
it onto the mounting shelf.
Figure 68 on page
153):