Mib Ii (Rfc 1213) System Group - Paradyne GranDSLAM 4200 User Manual

Atm stackable dslam
Hide thumbs Also See for GranDSLAM 4200:
Table of Contents

Advertisement

MIB II (RFC 1213)
The objects defined by MIB II (RFC 1213) are organized into the following groups:
T
T T
T

MIB II (RFC 1213) System Group

System Group objects are fully supported by the GranDSLAM 4200, as shown in
Table C-2, System Group
Table C-2. System Group Objects (1 of 2)
Object
Description
sysDescr
Provides a full name and
(system 1)
version identification for the
GranDSLAM system's
hardware and software.
sysObjectID
Identifies the network
(system 2)
management subsystem for
the GranDSLAM 4200.
sysUpTime
Provides the time (in hundreths
(system 4)
of a second) since the network
management portion of the
system was last reinitialized.
sysContact
Provides the contact
(system 4)
information for the person
managing the node.
sysName
Provides a contact name for
(system 5)
the node.
4200-A2-GB20-00
System Group (see
MIB II (RFC 1213) System Group
IP Group – Supported at a minimum. No tables or objects containing an IP
address are supported.
SNMP Group – Objects that apply to a management agent are fully
supported:snmpInPkts (snmp1), snmpOutPkts (snmp2), snmpInBadVersions
(snmp3, snmpInBadCommunityUses (snmp5), snmpInASNParseErrs
(snmp6), snmpInTotalReqVars (snmp13), snmpInTotalSetVars (snmp 14),
snmpInGetRequests (snmp15), snmpInGetNexts (snmp 16),
snmpInSetRequests (snmp 17), snmpInGetResponses (snmp 18),
snmpInTraps (snmp 19), snmpOutTooBigs (snmp 20),
snmpOutNoSuchNames (snmp21), snmpOutBadValues (snmp21),
snmpOutGenErrs (snmp24), snmpOutGetResponses (snmp28),
snmpOutTraps (snmp29), and snmpEnableAuthenTraps (snmp30).
Objects.
Setting/Contents
The object is set to display a string in the following format:
Paradyne Ubiquity ATM Stackable DSLAM; Model: xxxx ;
S/W Release: yy.yy.yy; CCA number: zzzz- zzz;
Serial number: sssssss ;
Where:
T
T
T
T
OIDs (Object Identifiers):
T
T
T
ASCII character string (32 characters), as set by the user.
T
ASCII character string (32 characters), as set by the user:
T
ASCII character string (32 characters), as set by the user:
T
August 2002
xxxx : Full model number of the unit
yy.yy.yy : Software revision number
zzzz-zzz : Hardware revision number of the parentboard
sssssss : Unit serial number
atm-stackable: [company enterprise OID].1.14.18
atms:stack – [company enterprise OID].1.14.18.1
atms:4200 – [company enterprise OID].1.14.18.1.1
badValue(3) – Field length exceeded.
badValue(3) – Field length exceeded.
badValue(3) – Field length exceeded.
C. Traps and MIBs
)
C-7

Advertisement

Table of Contents
loading