Table 10-6.
Example
Retrieve all service-affecting critical alarms for Network Termination Unit B.
RTRV-ALM-EQPT:TAMPA:NTB::CR,,SA;
M
module"
;
Related Commands
None
4200-A2-GB20-00
RTRV-ALM-EQPT Response Parameters (2 of 2)
Parameter
Explanation
cond_eqpt
Equipment condition. Valid values are:
EQPT: Equipment failed self-test
FANALM-1: Fan alarm for fan 1
FANALM-2: Fan alarm for fan 2
PROGVER: Failed to load or find requested software or configuration
file
RMTDLFAIL: Failed to download software or configuration
SWROLLBACK: Software version rolled back
serveff
As described for command parameters (see
RTRV-ALM-EQPT Command
[cond_descr]
Description of alarm condition
TAMPA 02-06-27 03:38:43
42 COMPLD
/* RTRV-ALM-EQPT:TAMPA:NTB:42::CR,SA
":NTB,EQPTS:CR,INT,SA,,,NEND,RCV,:Unknown error in
August 2002
10. Fault Commands
Table 10-5,
Parameters), except that ALL is not used.
*/
10-11