13. Synchronization Commands
ED-SYNCN
The ED-SYNCN Command configures the reference source for synchronization of
the NE clock.
Table 13-1.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:
After the above response, a new command input may be generated.
Normal Response:
M
;
Error Response:
M
;
13-2
ED-SYNCN Command Parameters
ED-SYNCN:[tid]:[aid_syncn]:[ctag]:::[syncn_nblk];
Restrictions: All parameters in this command are position-defined.
[tid]
Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.
[aid_syncn]
AID of the NE clock. The value is CLKSRCNT.
[ctag]
Correlation tag (6 characters maximum) that links an input command
with associated output responses. The default is 0.
syncn_nblk
Named parameter block for SYNCN. The block consists of one or more
of the following parameters, in any order separated by commas, each
followed by an equal sign and a valid value. If not specified, the value of
this parameter remains unchanged.
PRICREF: Primary reference source for synchronizing the clock. Valid
values are:
– LOOP: Loop timing recovered from network side facility
– LOCAL: Local oscillator on NT board
IP c
sid yy-mm-dd hh:mm:ss
c COMPLD
/* ED-SYNCN:[tid]:[aid_syncn]:[ctag]:::[syncn_nblk] */
sid yy-mm-dd hh:mm:ss
c
DENY
/* ED-SYNCN:[tid]:[aid_syncn]:[ctag]:::[syncn_nblk] */
aid:ERRCDE=errcde
/* error description */
August 2002