Response Format - Paradyne GranDSLAM 4200 User Manual

Atm stackable dslam
Hide thumbs Also See for GranDSLAM 4200:
Table of Contents

Advertisement

11. Log Commands
INIT-LOG
The INIT-LOG command initializes selected logs.
Table 11-1.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response will be sent:
After the above response, a new command input may be generated.
Normal Response:
M
;
Error Response:
M
;
11-2
INIT-LOG Command Parameters
INIT-LOG:[tid]:[logid]:[ctag]::lognm;
RESTRICTIONS: All parameters in this command are position-defined.
[tid]
The identification of the target NE. TID is optional and has a default
value of null. The NE's SID code is the only other valid value.
logid
COM is the only allowed value other than NULL for the AID field.
[ctag]
The correlation tag that correlates an input command with its associated
output response(s). It is assigned by the originator of the command. The
value is limited to six characters, which may be an identifier or a decimal
numeral. It is optional with a default of 0.
lognm
Names of logs to be initialized. Valid values are:
UNKCELL [aid_atmport]: Unknown cell log for the ATM interface (see
ED-ATMPORT).
SYSTEM: System log containing records of all significant system events
(alarms, events, database chages, ftp file transfer status, and security
messages).
ALL: All logs.
IP c
sid yy-mm-dd hh:mm:ss
c COMPLD
/* INIT-LOG:[tid]:[logid]:[ctag]::lognm */
sid yy-mm-dd hh:mm:ss
c
DENY
/* INIT-LOG:[tid]:[logid]:[ctag]::lognm */
errcde
August 2002
4200-A2-GB20-00

Advertisement

Table of Contents
loading

Table of Contents