Example; Related Commands - Paradyne GranDSLAM 4200 User Manual

Atm stackable dslam
Hide thumbs Also See for GranDSLAM 4200:
Table of Contents

Advertisement

Table 5-6.

Example

Edit rack 1, shelf 1, slot 1, circuit 9 to have an OAM segment location ID of all
ones.
ED-ATMPORT:TAMPA:LTATM-1-1-1-9:42:::SEGID=ALLONES
M
;

Related Commands

RTRV-ATMPORT
4200-A2-GB20-00
ED-ATMPORT Response Parameters
Parameter
Explanation
tid
Target NE identification
yy-mm-dd
Year, month, and day
hh:mm:ss
Hour, minute, and second
M
Message generated in response to an input command
c
If provided, ctag; otherwise 0
COMPLD
Completed
DENY
Input command is denied
/* */
Enclosed are human readable comments – unspecified format
errcde
Error code (see
atmport_nblk
SEGID: ATM segment location ID. A 16-octet field that identifies this
ATM interface for OAM F5 loopbacks. When a segment F5 OAM
loopback cell is received, the destination segment location in the cell is
compared to the segment location ID for the card. If the destination
location ID matches the location ID or is all ones, the cell is looped back
to the source. If there is not a match, the cell passes through the card.
The value is entered as 32 hexadecimal characters or ALLONES
(default). Allowed values are restricted per ITU-T1.610 as follows:
T
The first byte must be 01, 02, 03, FF or 6A.
T
If the first octet is FF, then octets 2 16 must also be FF.
T
If the first octet is 6A, then octets 2 16 must also be 6A.
If no value is specified for this field, then this parameter remains the
same.
TAMPA 01-11-24 12:30:43
42 COMPLD
/* ED-ATMPORT:TAMPA:LTATM-1-1-1-9:42:::SEGID=ALLONES */
on page 5-13
August 2002
Appendix A, Error Codes
)
5. ATM Commands
5-7