The INIT-SYS command initializes or resets selected subsystems in the NE.
Table 14-10. INIT-SYS Command Parameters
Response Format
If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response will be sent:
After the above response, a new command input may be generated.
Normal Response:
M
;
Error Response:
M
;
4200-A2-GB20-00
INIT-SYS:[tid]:aid_proc:[ctag]::init_mode;
RESTRICTIONS: All parameters in this command are position-defined.
[tid]
The identification of the target NE. TID is optional and has a factory
default value of null. The NE's SID code is the only other valid value.
aid_proc
Identifier of the processor to be initialized. The value can be preceded
with AID= (not required).Grouping and ranging are not allowed. The
only valid value is SYSTEM.
[ctag]
Correlation tag (1 6 characters) that links an input command with
associated output responses. The default is 0.
init_mode
Mode of initialization. Valid values are:
1= Initialize with extended self-test.
2 = Initialize with minimum self-test.
3 and 4 are reserved.
20 = Complete reset (all user options are reset to factory defaults).
IP c
sid yy-mm-dd hh:mm:ss
c COMPLD
/* INIT-SYS:[tid]:aid_proc:[ctag]::init_mode */
sid yy-mm-dd hh:mm:ss
c
DENY
/* INIT-SYS:[tid]:aid_proc:[ctag]::init_mode */
aid:ERRCDE=errcde
/* error description */
August 2002
14. System Commands
14-11