Configure a Pulse Wave
Description
A pulse wave has amplitude, offset, and phase relative to sync pulse. It also adds edge slope, period, and duty cycle (or
pulse width, depending on the
and low voltage values.
Example
The following waveform can be set up with the series of SCPI commands, where high and low can be used in place of
SOUR:VOLT
and SOUR:VOLT:OFFS.
The following commands produce the pulse wave shown above.
FUNCtion PULS
FUNC PULS
FUNC:PULS:HOLD WIDT
FUNC:PULS:TRAN:LEAD 8E-8
FUNC:PULS:TRAN:TRA 1.3E-7
FUNC:PULS:WIDT 1E-6
FREQ 6E5
VOLT 3
OUTP ON
Remarks
You can use
FUNC:PULS:PER
l
Pulse can be specified by width or duty cycle, which are also coupled. Use
l
that duty cycle is held constant value as frequency or period changes. Use
ify that pulse width is held constant as frequency or period changes.
Agilent 33500 Series Operating and Service Guide
FUNC:PULSe:HOLD
configuration). Its amplitude and offset can also be set using high
instead of FREQ. These commands are paired; changing one changes the other.
Configure a Pulse Wave
FUNCtion:PULSe:HOLD DCYC
FUNCtion:PULSe:HOLD WIDTh
to specify
to spec-
331