Configure a Square Wave
Description
A square wave has amplitude, offset, and phase relative to sync pulse. It also has duty cycle and period. Its amplitude
and offset can also be set using high and low voltage values.
Example
The following waveform can be set up with the series of SCPI commands, where high and low can be used in place of
SOUR:VOLT
and SOUR:VOLT:OFFS.
The following commands produce the square wave shown above.
SOUR:FUNCtion SQU
SOUR:FUNCtion:SQUare:DCYCle +10.0
SOUR:FREQ +1.0E+03
SOUR:VOLT +2.0
SOUR:VOLT:HIGH +2.0
SOUR:VOLT:LOW +0.0
SOUR:VOLT:OFFS +1.0
OUTPut1 1
SOUR:PHAS +90.0
Remarks
For Square Wave, if you change SOUR:FREQ, the
l
+2.0E+03 is equivalent to SOUR:FUNC:SQU:PER +5.0E-04.
Agilent 33500 Series Operating and Service Guide
SOUR:FUNC:SQU:PER
will change. For example, SOUR:FREQ
Configure a Square Wave