Default names are "AUTO_RECALL", "STATE_1", "STATE_2", "STATE_3", and "STATE_4".
l
You can name location 0, but the name is overwritten when power is cycled and a new power-down state is stored
l
there.
MEMory:STATe:DELete {0|1|2|3|4|}
Deletes a state storage location.
Parameter
{0|1|2|3|4|}
(none)
Delete the contents of storage location 1:
MEM:STAT:DEL 1
Default names are "AUTO_RECALL", "STATE_1", "STATE_2", "STATE_3", and "STATE_4".
l
Although you may delete the state in location 0, it will be restored to its
l
("AUTO_RECALL") at the next power up.
Attempting to recall a state from an empty location generates an error.
l
MEMory:STATe:NAME {0|1|2|3|4} [,< name >]
MEMory:STATe:NAME? {0|1|2|3|4}
Names a storage location.
An unquoted string of up to 12 characters.
The first character must be a letter (A-Z).
Others can be letters, numbers (0-9), or underscores ("_").
If name omitted, factory default name is used.
Rename location 1:
MEM:STAT:NAME 1,TEST_RACK_1
Default names are "AUTO_RECALL", "STATE_1", "STATE_2", "STATE_3", and "STATE_4".
l
You can name location 0, but the name is overwritten when power is cycled and a new power-down state is stored
l
there.
May assign same name to different locations.
l
Deleting a storage location's contents (MEMory:STATe:DELete) resets associated name to factory default ("AUTO_
l
RECALL", "STATE_1", "STATE_2", "STATE_3", or "STATE_4").
State names are unaffected by *RST.
l
MEMory:STATe:RECall:AUTO {ON|1|OFF|0}
MEMory:STATe:RECall:AUTO?
Disables or enables automatic recall of instrument state in storage location "0" at power on.
Agilent 33500 Series Operating and Service Guide
Typical Return
Parameter
factory default
Typical Return
TEST_RACK_1
MEMory Subsystem
state, and state name
247

Advertisement

loading