Chart Speed Programming - Omega RD2800 Series User Manual

Hybrid recorders
Table of Contents

Advertisement

8.
BASIC PROGRAMMING
Program the chart speed before operation.
1
• Press
and
SHIFT
CHART
operation screen to display the [Chart speed]
programming screen.
• For the remote contacts (option), read Section13.3.
• 0000mm/h can be set for RD2800. When 0000mm/h is
set, chart is fed at the speed of 12.5mm/h.
1
Programming Mode

Cursor Chart speed (4 digits programming)
(Fixed)
Speed unit
(H/M)
2
Programming Flow Chart
<Example> From 20 mm/h to 50 mm/h
[Check]

Speed unit
[To be ready for programming]

[Programming chart speed]

YES
Error message appears?
Keys other than
SHIFT
If 150 mm/h or more is
Remarks 1
programmed for the chart speed
No printing, except time line, data printing and
programming change mark, is executed.

8.4 Chart Speed Programming

simultaneously in the

Operation screen
SHIFT

Chart speed
SET
END

Cursor
0
0
CLEAR
CLEAR

Cursor
ENTRY
NO
Stored
Move the cursor to the character
display (a digit on the left) then press
DISP
"H" alternatively.
1
CHART
Programmed chart speed
• Cursor and programming lamp light.
• Cursor moves rightward when
0
5
DATA I
CLEAR
Program the chart speed within 0001
to 0600 mm/h or 0001 to 0200
mm/min.
An error occurs if a value exceeds the
programming range or any space or
decimal point is entered.
The new programmed value is stored
into memory.
Influence to periodic data printing
Remarks 2
When changing the chart speed, the programmed
parameters for [periodic data printing] (Section 11.7)
is cleared. (Default: Not programmed)
-44-
Programming range
0001 to 0600 (mm/h)
or
0001 to 0200 (mm/h)
Character display
Programming lamp
Speed unit
(H or M)
Memory colon
Cursor
Changing the speed unit (h/m)
or
to switch "M" and
/
%
pressing a numeric key.
Cursor moves rightward.
Cursor moves leftward.
Memory colon blinks and the
programming change mark
printed.
is

Hide quick links: