Skip (Channel Deletion) - Omega RD2800 Series User Manual

Hybrid recorders
Table of Contents

Advertisement

11. OTHER PROGRAMMING
When "CLEAR" (non-programming condition) is stored in the [Range/Printing range] programming, printing and
display of specific channels are skipped. Press
[Range/Printing range] programming screen. The default is no skip function programmed to any channel.
1
Skipping
If the skip function is programmed to the specified
channel, programmed parameters of [scale],
[alarm], [engineering unit] and [tag] of this channel
are also cleared. Program the parameters again if
the channels are restored to no-skipped status.
2
Programming Skip Flow Chart
<Example> Skipping CH 3 (3rd pen)
Operation screen
[Check]

Channel
[To be ready for programming]

Cursor
[Selecting channel]

Channel
[Programming clear]
Channel
YES
Skipping other channels?
SHIFT
7
SHIFT
RANGE
SET
END
or
/
(Press several times)
0
SHIFT
CLEAR
ENTRY
Temporarily stored
NO
SET
SHIFT
END
Stored
Ref. 2
-59-

11.3 Skip (Channel Deletion)

7
and
in the operation screen to display the
RANGE
Operation of skipped channels
Your recorder functions assuming that these
channels do not exist.
(1) Measured value: Disappear
(2) Bargraph: Disappear
(3) Data printing: Disable
(4)Trace printing: Overshooting to the minimum limit.
Remarks
DISP
Select a channel with
If a channel is selected with a numeric
Ref. 1
key and the "CLEAR" is executed, the
channel being displayed before
changing programming ([1] in the flow
chart) is deleted.
%
Reference 1
Remarks
You can check the range
programming of other channels.
Press
channels. The skipped channels are
not displayed.
Reference 2
Store the [temporarily stored] skip into
the memory. (A programming change
mark is printed.)
To select channels
or
%
/
Other channel check
or
to change
/
%
Storing
.