14. PRINTING FORMAT
This programming display only appears for the
printing format (option). This programming is to
print
the
specified
[compressed/expanded] printing mode.
1
Compressed/Expanded printing
A specified range in the trace printing range
can be printed in the compressed or
expanded printing mode.
(1) This programming can be executed for
each channel.
(2) The printing range can be programmed
optionally irrespective of the programmed
range in the [Range/Printing range].
(3) Up to 2 break points can be programmed.
2
Programming Mode
1) Screen 1 (Printing format check)


Automatic
Standard
range shift
Dots appear at the selected format.
SET
By pressing
, the dots disappear and the
END
cursor appears instead.
2) Screen 2 (Programming channel)
Programming mode of compressed/expanded

No. 1 break
Cursor
Channel
point
By selecting compressed/expanded (   ), the
cursor appears at the channel programming
position.
14.2
range
in
the
Printing range
Mark
order of programming. By pressing
programming ends, the next programming screen appears.
(Program No.1 break point and No.2 break point by 2 digits.
<Example> 5% →05)


Zone
Compressed/expanded
No. 2 break
point
-94-

Programming Compressed/Expanded Printing

<Example> Compressed and expanded programming
<Range No. 23 (K thermocouple)>
Measuring value
-100
-200
Com-pre
ssed
(1)
Printing
20%
0%
position
(No. 1 break point)
(2)
(3)
Scale
-100
600
is the programming point and No. (1) to (5) shows the
3) Screen 3 (Programming break point printing
position)

Programming No. 1
break point
(1) Program each break point printing position (%) in
the range of 10 to 90.
(2) When all programming are completed, return to
the above display and execute [Storing].
(Note) No.1 break point should be lower than No.2
break point. When no programming for the
No.2 break point is required, leave it as
spaces.
4) Screen 4 (Scale programming of each
printing position)

(1) When programming a scale, the printing position
advances to the next position. Program scales
up to the 100% position.
(2) After completing the programming for 100%,
press
ENTRY
to return to Screen 3.
600 800
1200
1370
Com-pre
Expanded
ssed
(1)
80%
100%
(No. 2 break point)
(4)
(5)
1200
800
ENTRY
after the
 

Programming No. 2
break point (Note)
Printing position (%)

Programming value
(Max. 5 digits by left-justify)