Safety Regulations - Omega RD2800 Series User Manual

Hybrid recorders
Table of Contents

Advertisement

22. SPECIFICATIONS
6
Operation Conditions
Operation conditions: Refer to the following table
Reference
Items
operation
Ambient
21 to 25°C
temperature
Max. ambient
80%RH
humidity
Min. ambient
20%RH
humidity
Power supply
100VAC ± 1%
voltage
Power supply
50/60Hz ± 0.5%
frequency
Left/right
Forward
Posture
tilting
Backward
tilting
Warming-up time
30 min. or more
*Decrease from 80% RH at 31°C, and decrease to 50% at
40°C
Transportation condition:
Ambient temperature/humidity... -20 to 60°C, 5 to 90%RH
Vibration...10 to 60Hz, 4.9 m/S
2
Impact...392 m/S
*
* When shipping out from a factory
Storage condition:
Ambient temperature/humidity... -20 to 60°C, 5 to 90%RH
7
General specifications
Rated power voltage: 100 to 240 VAC, 50/60 Hz
Power consumption: Maximum 60V A
Power failure protection: Programmed parameters stored
into EEPROM memory. Clock circuit sustained for
minimum 8 years by a lithium battery. (8 hours
operation per day)
Insulation resistance:
Between primary and protective conductor terminals
...20MΩ or more at 500 V DC
Between secondary and protective conductor terminals
...20MΩ or more at 500 V DC
Between primary and secondary terminals
...20MΩ or more at 500 V DC
Dielectric strength:
Between primary and protective conductor terminals
...1 minute at 1500 V AC
Between secondary and protective conductor terminals
...1 minute at 500 V AC
Between primary and secondary terminals
...1 minute at 2300 V AC
Primary terminals: Power terminals, Alarm output terminals
(MOS relay, mechanical relay "a" contact)
Secondary terminals: Measuring input terminals, Remote
contacts
terminals,
terminals , Alarm output terminals (Mechanical relay "c"
contact),
Case assembly material: Door Frame ...ABS resin
Front plate...Polycarbonate
Enclosure...Steel
Normal operation
31 to
0 to 31°C
50°C*
80 to
80%RH
50%RH*
20%RH
90 to 264VAC
50/60Hz ± 2%
0 to 10°
0 to 30°
Not necessary
(without condensation)
2
*
(without condensation)
Communications
interface
-128-
Color: Door ... Frame: Black (equivalent to Munsell N3.0)
Front plate: Transparent
Enclosure...Gray (equivalent to Munsell N7.0)
Mounting: Panel mounting
Terminal screws: Power terminals ...M4.0
Terminals other than above ...M3.5
Weight: RD200 ...Approx. 4.0 kg (with fully options)
RD2800 ...Approx. 9.0 kg (with fully options)
Dimension: RD200...144×144×258 (mm)
RD2800...288×288×220 (mm)
Panel cutout:RD200...138×138 (mm)
RD2800...281×281 (mm)
Clock accuracy: Within ±2 minutes per 30 day
(Under reference operating conditions,
Except errors when power supply is turned
on or off)
Packing material: Layered cardboard is used as cushion
material
8

Safety Regulations

CE: Conforms to EMC and low voltage directives
UL: UL3111-1 (Approval pending)
CSA (C-UL): CSA ...C22.2 No.1010 (Approval pending)
IP: Conforms to IEC529 IP54

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd200 series

Table of Contents