Omega RD2800 Series User Manual page 40

Hybrid recorders
Table of Contents

Advertisement

7. PROGRAMMING
Programming
Names
items
Chart speed
(3 speeds)
Terminal
Remote
allocation
contacts
Operation
record
Automatic
range shift
(Ar)
Record
format
Compressed/
Expanded
(SP)
Zone scale
(PL)
Protocol
Communi-
cations
interface
Specifications
* RD200: 20 mm/h, RD2800: 25 mm/h
7.3 List of Programming Items
Programming
Key operations
contents
Speed No.
1
SHIFT
CHART
Speed
Terminal No.
0
5
CLEAR
DATA I
(3 sec. or more)
Operation
Printing No.
0
2
CLEAR
TAG
(3 sec. or more)
Printing
position
Format
Channel
Zero for range 1
Span for range 1
SHIFT
DISP
Span for range 2
Span for range 3
Span for range 4
Span for range 5
Format
Channel
Printing position
for broken point 1
Printing position
for broken point 2
SHIFT
DISP
Scale at zero
Scale for broken
point 1
Scale for broken
point 2
Scale for span
Format
CH for area 1
SHIFT
DISP
CH for area 2
CH for area 3
CH for area 4
SPACE
SHIFT
COPY(=)
For details, refer to the separate instruction manual for
(3 sec. or more)
"Communications Interface".
SHIFT
(-)
(3 sec. or more)
-36-
Defaults
Programming ranges
1
1 to 3
0001 to 0600 mm/h or 0001 to 0200
20/25*
mm/min
1
1 to 4
Selection from 13 items;
non, printing on/off & 3 kinds of chart
speed, message printing (No. 1 to 2),
non
message printing (No. 1 to 5), operation
record (A/B/C/D), digital data printing, list
printing (No. 1to 3) and totalizing reset
A
A, B, C, D
10 to 90%.
Printing position when the contact is
0
open. The printing position is at +5 mm
when it is shorted.
Select Ar from Sd (standard), Ar, SP, and
Sd
PL.
Not
1 to 4
programmed
Not
a (Minimum value ≤ a < b)
programmed
Not
b (a < b < c)
programmed
Not
c (b < c < d)
programmed
Not
d (c < d < e)
programmed
Not
e (d < e < f)
programmed
Not
f (e < f ≤ maximum value)
programmed
Select SP from Sd (standard), Ar, SP, and
Sd
PL.
Not
1 to 4
programmed
Not
0 to a (%)
programmed
Not
a to 100 (%)
programmed
Not
b (Minimum value ≤ b < c)
programmed
Not
c (b < c < d)
programmed
Not
d (c < d < e)
programmed
Not
e (d <e≤ maximum value)
programmed
Select PL from Sd (standard), Ar, SP, and
Sd
PL.
Not
1 to 4
programmed
1 to 4 (Except channels for
Not
area 1)
programmed
1 to 4 (Except channels for
Not
area 1 and 2)
programmed
1 to 4 (Except channels for
Not
area 1 to 3)
programmed
Ref.
page
13.3
13.2
13.4
14.1
14.2
Area 1
14.3
and 2
only for
RD200
15.1
15.2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd200 series

Table of Contents