14. PRINTING FORMAT
3
Programming Flow Chart
Operation screen
[Checking printing format]
     
(1)
Standard
[To be ready for programming]
     
(2)
Cursor
[Selecting
compressed/expanded]
 
(3)
Channel
[Programming channel]
   
(4)
Channel
[Programming printing position
for each break point]
      
(5)
[ Programming scale of printing
position0%]
  
(6)
Printing position
Printing position (%) changes. Program the
corresponding scale and press
(7)
programming. Continue this programming up to 100%
scale.
Remarks 1
[Returning to the step (5)]
      
(8)
Other channel programming
This programming is necessary for each channel. For
programming other channels, repeat the procedure from the
"Operation screen".
14.2
<Example> Programming the details on the left page for CH 2
DISP
SHIFT
+
SET
END
Compressed
/Expanded
No.1 break
No.2 break point
point
2
ENTRY
TAG
2
0
8
TAG
CLEAR
ALARM
0
ENTRY
CLEAR
×4
0
SPACE
CLEAR
COPY(=)
ENTRY
 
*
Scale
for every
ENTRY
ENTRY
SET
+
SHIFT
END
Stored
Ref. 2
-95-
Programming Compressed/Expanded Printing
DISP
Remarks 1
Press any key other than
Ref1
and program again. When it is normal,
the next screen appears.
Remarks 2
Leave it as spaces and press
Remarks 3
For storing parameters into memory,
return the screen to Step (5).
ENTRY
Reference 1
Press
ENTRY
The parameters are displayed
Remarks 1
sequentially each time
pressed. Press
change channels.
Remarks 1
Reference 2
Remarks 2
Store the parameters into memory.
(Programming
printed.)
Remarks 1
Reference 3
For canceling the stored parameters,
press
SHIFT
simultaneously at Steps (4) to (7), and
then press
cancellation.
Reference 4
Point the cursor to (  ) at Step (2)
and press
Remarks 3
compressed/expanded
execute the procedure of Steps (1) to
(3) and store it.
Reference 5
Scales at each printing position are
printed like as –100, 600, 800 or1200.
• "+" mark is printed at the printing
position for break points.
* Fill unused digits with spaces.
Remedial measure to
error display
SHIFT
No programming of No. 2
break point necessary
.
ENTRY
Return to the screen of
Step (5)
Checking parameters
to display parameters.
ENTRY
is
or
to
/
%
Storing
change
mark
is
Cancellation of programming
0
and
CLEAR
to store the
ENTRY
Returning to
standard printing
. To return to the
ENTRY
function,
Scale printing at
fixed time printing