7. PROGRAMMING
1
Parameters to be Programmed First
Parameters
Key operations
Range/
printing
+
SHIFT
range *
°C/°F
SHIFT
+
calculation
(3 sec. or more)
Chart speed
+
SHIFT
* RD200: 20 mm/h, RD2800: 25 mm/h
2
Other Programmable Parameters and Functions
Parameters
Key operations
Clock
+
SHIFT
Scale *
+
SHIFT
SHIFT
Skip *
+
Subtract
+
printing *
SHIFT
Alarm
SHIFT
* Programming is required to each channel. For 1-pen type, programming is only for CH 1. The items without *
mark are programming common to all channels. For "alarm", programming is required to each level of
channels.

7.3 List of Programming Items

Programming
Defaults
items
Range No.
07
RJ enable/
0
7
disable
RANGE
Printing
0.000 to 5.000
range
°C
1
20/25 *
CHART
Programming
Defaults
items
Japanese
CLOCK
time
4
0.000 to 5.000
SCALE
Not
7
RANGE
programmed
Not
7
programmed
RANGE
CH/output
Not
type
programmed
Not
Level
programmed
Alarm
H
types
8
ALARM
Relay No.
0
Alarm
Not
values
programmed
Measuring
Not
count
programmed
Not
Ref. CH
programmed
-34-
Programming ranges
01 to 10, 21 to 56, 70 to 80
0 (disable), 1 (enable: thermocouple range only)
Max. 10 digits (minimum value to maximum
value). Excluding decimal point.
°C (°C calculation) °F (°F calculation)
Thermocouple and resistance thermometer
range only
0001 to 0600 mm/h or 0001 to 0200 mm/min.
Programming ranges
2000.01.01.00:00 to 2099.12.31.23:59
Max. 11 digits (minimum value to maximum value),
excluding decimal point. Printing range reflects to the
scale. Therefore no programming is normally
necessary
for
thermocouple
thermometer range.
Programming is required in [Range/Printing range]
programming mode.
• Channel to be deleted →Clear the range/printing
range.
• Channel to be recovered →Program the range/
printing range.
Programming is required in [Range/Printing range]
programming mode.
[Subtract printing CH] = [Reference CH] – [subtraction CH*]
* Can be replaced with [reference value (with decimal
point)].
Select from CH (1 to 4), Fail* or C.End (chart end).
* Recorders with alarm output (option) only.
Up to 4 alarm points can be programmed to each
channel (CH 1 to 4).
Applicable to CH (1 to 4) selected in CH/output type
mode.
H/L (absolute value high/low limits)
E/F (absolute value high/low limits with standby)
U/d (rate-of-change increase/decrease limits)
b/S (differential high/low limits)
J/k (differential high/low limits with standby)
Applicable to recorders with alarm output (option)
Relay No. "0" to "n" can be programmed. ("0": no
output), n: number of output points.
For recorders without alarm output (option), the
number is fixed as "0".
Max. 5 digits including (-) sign.
Sign is not necessary when U/d, b/S or J/k is selected.
1 to 20, Programming required only when U/d is
selected.
1 to 4, Programming required only when b/S and J/k
are selected.
Ref.
page
8.2
8.3
8.4
Ref.
page
11.1
11.2
and
resistance
11.3
11.4
11.5

Hide quick links:

Advertisement