Barco DP2K-E series User And Installation Manual page 97

Hide thumbs Also See for DP2K-E series:
Table of Contents

Advertisement

Convergence test pattern
Image 12-2
The test pattern illustrated above is specifically designed for convergence purposes. The test pattern has three blue arrows num-
bered from 1 to 3 and three green arrows numbered from 4 to 6. These numbers and colors correspond to those of the control
knobs. Each knob is marked with an arrow which corresponds to the direction indicated on the screen.
Adjustment Range
Prevent damage to the system by limiting the amount/number of adjustment(s) made. Typically the convergence adjustments serve
to correct a convergence fault of a few pixels at the most. Any convergence fault beyond this is considered grossly abnormal and
likely indicates abuse or rough handling. However, in extreme cases correction of up to 10 pixels is possible.
C
AUTION
damage. Please handle gently.
Troubleshooting 'dead zone' of control knob
In the rare event that a knob is loose in the perfect convergence position, it is preferable to continue translating the image away for
approximately 20 to 30 pixels (max 1 revolution of the knob(s)). Note that this is the only time we allow for extreme adjustment.
Thereafter, return the image back immediately to the correct position. The knob should now have become tighter in the final position
and therefore resists turning due to vibrations and such. Repeat the procedure if you feel the knob is still loose.
R5906693 DP2K-E SERIES 19/06/2015
1
2
5
2
5
:
The system does have an end of travel in either direction, but using excessive force may cause
4
1
4
12. Convergence
3
6
3
6