Dsa Emulex Adapter Test Results - Lenovo x3550 M4 Installation And Service Manual

Hide thumbs Also See for x3550 M4:
Table of Contents

Advertisement

089-804-000 • 516-800-000
Latest level of BMC/IMM
v
089-804-000
CPU Stress Test Aborted
Explanation: CPU Stress Test Aborted. User pressed
Ctrl-C.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
089-901-000
CPU Stress Test Failed
Explanation: CPU Stress Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No

DSA Emulex adapter test results

The following messages can result when you run the Emulex adapter test.
516-000-000
ELXUCNA: NIC MAC LoopBackTest
Passed
Explanation: The test passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
516-001-000
ELXUCNA: NIC PHY LoopBackTest
Passed
Explanation: The test passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
v
IBM Support Website
540
System x3550 M4 Type 7914: Installation and Service Guide
Automatically notify Support: No
User response: Complete the following steps:
1. If the system has stopped responding, turn off and
restart the system and then run the test again.
2. Make sure that the DSA Diagnostic code is at the
latest level.
3. Run the test again.
4. Check system firmware level and upgrade if
necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component.
5. Run the test again.
6. If the system has stopped responding, turn off and
restart the system and then run the test again.
7. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
Latest level of DSA
v
v
Latest level of BMC/IMM
516-002-000
ELXUCNA: ELXUCNA: NIC
LED(Beacon)Test Passed
Explanation: The test passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
IBM Support Website
v
Latest level of DSA
v
v
Latest level of BMC/IMM
516-800-000
ELXUCNA: NIC MAC LoopBackTest
Aborted
Explanation: Loopback testing at the MAC layer was
canceled.
Severity: Warning
Serviceable: No
Recoverable: No

Advertisement

Table of Contents
loading

Table of Contents