Lenovo x3550 M4 Installation And Service Manual page 392

Hide thumbs Also See for x3550 M4:
Table of Contents

Advertisement

800b050a-1e82ffff • 806f0007-0302ffff
CIM Information: Prefix: PLAT and ID: 0810
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Make sure that the connectors on fan n are not
damaged.
2.
Make sure that the fan n connectors on the system
board are not damaged.
3.
Make sure that the fans are correctly installed.
4.
Reseat the fans.
5.
Replace the fans. (n = fan number)
800b050a-1e82ffff
Non-redundant:Insufficient
Resources for
[RedundancySetElementName] has
asserted. (Fan Zone 2)
Explanation: This message is for the use case when a
Redundancy Set has transitioned to
Non-redundant:Insufficient Resources.
May also be shown as 800b050a1e82ffff or
0x800b050a1e82ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0810
SNMP Trap ID: 11
Automatically notify Support: No
User response:
Make sure that the connectors on fan n are not
1.
damaged.
Make sure that the fan n connectors on the system
2.
board are not damaged.
Make sure that the fans are correctly installed.
3.
Reseat the fans.
4.
5.
Replace the fans. (n = fan number)
800b050c-2581ffff
Non-redundant:Insufficient
Resources for
[RedundancySetElementName] has
asserted. (Backup Memory)
Explanation: This message is for the use case when a
Redundancy Set has transitioned to
Non-redundant:Insufficient Resources.
May also be shown as 800b050c2581ffff or
0x800b050c2581ffff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
374
System x3550 M4 Type 7914: Installation and Service Guide
CIM Information: Prefix: PLAT and ID: 0810
SNMP Trap ID: 41
Automatically notify Support: No
User response:
1.
Check the system-event log for DIMM failure
events (uncorrectable or PFA) and correct the
failures.
2.
Re-enable mirroring in the Setup utility.
806f0007-0301ffff
[ProcessorElementName] has
Failed with IERR. (CPU 1)
Explanation: This message is for the use case when an
implementation has detected a Processor Failed - IERR
Condition.
May also be shown as 806f00070301ffff or
0x806f00070301ffff
Severity: Error
Alert Category: Critical - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0042
SNMP Trap ID: 40
Automatically notify Support: No
User response:
1.
Make sure that the latest level of firmware and
device drivers are installed for all adapters and
standard devices, such as Ethernet, SCSI, and SAS.
Important: Some cluster solutions require specific
code levels or coordinated code updates. If the
device is part of a cluster solution, verify that the
latest level of code is supported for the cluster
solution before you update the code.
2.
Update the firmware (UEFI and IMM) to the latest
level (Updating the firmware).
3.
Run the DSA program.
4.
Reseat the adapter.
5.
Replace the adapter.
6.
(Trained technician only) Replace microprocessor n.
7.
(Trained technician only) Replace the system board.
(n = microprocessor number)
806f0007-0302ffff
[ProcessorElementName] has
Failed with IERR. (CPU 2)
Explanation: This message is for the use case when an
implementation has detected a Processor Failed - IERR
Condition.
May also be shown as 806f00070302ffff or
0x806f00070302ffff
Severity: Error
Alert Category: Critical - CPU