Lenovo x3550 M4 Installation And Service Manual page 387

Hide thumbs Also See for x3550 M4:
Table of Contents

Advertisement

2.
If the problem persists, (trained technician only)
replace the system board (see Removing the system
board and Installing the system board).
80070219-0701ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (SysBrd Fault)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 800702190701ffff or
0x800702190701ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Check for an error LED on the system board.
2.
Check the system-event log.
Check for the system firmware version and update
3.
to the latest version. Important: Some cluster
solutions require specific code levels or coordinated
code updates. If the device is part of a cluster
solution, verify that the latest level of code is
supported for the cluster solution before you update
the code.
4.
Unplug and restore AC power cord, then, perform
step 1 and 2 again.
5.
If problems still occurred, (trained technician only)
replace the system board.
8007021b-0301ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (CPU 1 QPILinkErr)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 8007021b0301ffff or
0x8007021b0301ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Check for a server firmware update.
80070219-0701ffff • 80070301-0301ffff
2.
Make sure that the installed microprocessors are
compatible.
3.
Make sure the microprocessor 2 expansion board is
installed correctly (see Installing the microprocessor
2 expansion board).
4.
(Trained technician only) Replace microprocessor 2.
5.
(Trained technician only) Replace microprocessor 2
expansion board.
8007021b-0302ffff
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 8007021b0302ffff or
0x8007021b0302ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response:
Check for a server firmware update.
1.
Make sure that the installed microprocessors are
2.
compatible.
Make sure the microprocessor 2 expansion board is
3.
installed correctly (see Installing the microprocessor
2 expansion board).
(Trained technician only) Replace microprocessor 2.
4.
(Trained technician only) Replace microprocessor 2
5.
expansion board.
80070301-0301ffff
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
non-recoverable from less severe.
May also be shown as 800703010301ffff or
0x800703010301ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0524
SNMP Trap ID: 0
Automatically notify Support: No
Appendix A. Integrated management module II (IMM2) error messages
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (CPU 2 QPILinkErr)
Sensor [SensorElementName] has
transitioned to non-recoverable from a
less severe state. (CPU 1 OverTemp)