Dsa Checkpoint Panel Test Results - Lenovo x3550 M4 Installation And Service Manual

Hide thumbs Also See for x3550 M4:
Table of Contents

Advertisement

218-905-000 • 180-901-000
Latest level of DSA
v
Latest level of BMC/IMM
v
218-905-000
Brocade:SerdesEthLoopbackTest Failed
Explanation: A failure was detected during the
Loopback test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Rerun the test.
2. Verify whether the firmware is at proper level.
3. Rerun the test.
4. If the problem remains, contact your IBM
technical-support representative.
Related Links:
IBM Support Website
v
v
Latest level of DSA

DSA checkpoint panel test results

The following messages can result when you run the checkpoint panel test.
180-000-000
Check-point Panel Test Passed
Explanation: Check-point Panel Test Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
180-801-000
Check-point Panel Test Aborted
Explanation: Check-point Panel Test Aborted. BMC is
unable to verify that the operator information panel
cable is connected.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Inspect and reseat operator information panel cable
at both ends.
538
System x3550 M4 Type 7914: Installation and Service Guide
Latest level of BMC/IMM
v
218-906-000
Brocade:InternalLoopbackTest Failed
Explanation: A failure was detected during the
Loopback test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Rerun the test.
2. Verify whether the firmware is at proper level.
3. Rerun the test.
4. If the problem remains, contact your IBM
technical-support representative.
Related Links:
IBM Support Website
v
Latest level of DSA
v
v
Latest level of BMC/IMM
2. Verify that the Baseboard Management Controller
(BMC) is working.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
180-901-000
Check-point Panel Test Failed
Explanation: Check-point Panel Test Failed. Operator
reported incorrect display.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check the operator information panel cabling for
loose or broken connections at both ends or damage
to the cable.
2. Replace the information panel cable if damage is
present.
3. Run the test again.