CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 41
Automatically notify Support: No
User response:
1.
Check the system-event log for DIMM failure
events (uncorrectable or PFA) and correct the
failures.
2.
Re-enable mirroring in the Setup utility.
800b0309-1301ffff
Non-redundant:Sufficient
Resources from Redundancy Degraded
or Fully Redundant for
[RedundancySetElementName] has
asserted. (Power Resource)
Explanation: This message is for the use case when a
Redundancy Set has transitioned from Redundancy
Degraded or Fully Redundant to Non-
redundant:Sufficient.
May also be shown as 800b03091301ffff or
0x800b03091301ffff
Severity: Warning
Alert Category: Warning - Redundant Power Supply
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0806
SNMP Trap ID: 10
Automatically notify Support: No
User response:
1.
Non-redundant sufficient: Power load will be
handled by remaining power supply, though the
system may throttle to avoid a power supply
over-current condition.
2.
Replace the power supply with higher rated power.
800b030c-2581ffff
Non-redundant:Sufficient
Resources from Redundancy Degraded
or Fully Redundant for
[RedundancySetElementName] has
asserted. (Backup Memory)
Explanation: This message is for the use case when a
Redundancy Set has transitioned from Redundancy
Degraded or Fully Redundant to Non-
redundant:Sufficient.
May also be shown as 800b030c2581ffff or
0x800b030c2581ffff
Severity: Warning
Alert Category: Warning - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0806
SNMP Trap ID: 43
800b0309-1301ffff • 800b050a-1e81ffff
Automatically notify Support: No
User response:
Check the system-event log for DIMM failure
1.
events (uncorrectable or PFA) and correct the
failures.
Re-enable mirroring in the Setup utility.
2.
800b0509-1301ffff
Explanation: This message is for the use case when a
Redundancy Set has transitioned to
Non-redundant:Insufficient Resources.
May also be shown as 800b05091301ffff or
0x800b05091301ffff
Severity: Error
Alert Category: Critical - Redundant Power Supply
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0810
SNMP Trap ID: 9
Automatically notify Support: No
User response:
1.
Power load may be handled by remaining power
supply. The system will attempt to throttle to avoid
a power supply over-current condition. But a
system shutdown may happen anyway if the power
load is too great.
Reduce the total power consumption by removing
2.
newly added or unused options like drives or
adaptors.
Use the IBM Power Configurator utility to
3.
determine current system power consumption. For
more information and to download the utility, go to
http://www-03.ibm.com/systems/bladecenter/
resources/powerconfig.html.
4.
Replace the power supply with higher rated power.
800b050a-1e81ffff
Explanation: This message is for the use case when a
Redundancy Set has transitioned to
Non-redundant:Insufficient Resources.
May also be shown as 800b050a1e81ffff or
0x800b050a1e81ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
Appendix A. Integrated management module II (IMM2) error messages
Non-redundant:Insufficient
Resources for
[RedundancySetElementName] has
asserted. (Power Resource)
Non-redundant:Insufficient
Resources for
[RedundancySetElementName] has
asserted. (Fan Zone 1)
373