Lenovo x3550 M4 Installation And Service Manual page 472

Hide thumbs Also See for x3550 M4:
Table of Contents

Advertisement

806f0a13-0302ffff • 81010204-1d02ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0244
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Reseat the microprocessor, and then restart the
server.
2.
Replace microprocessor n. (n = microprocessor
number)
806f0a13-0302ffff
A Fatal Bus Error has occurred on
system [ComputerSystemElementName].
(CPU 2 PECI)
Explanation: This message is for the use case when an
implementation has detected a Bus Fatal Error.
May also be shown as 806f0a130302ffff or
0x806f0a130302ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0244
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Reseat the microprocessor, and then restart the
server.
2.
Replace microprocessor n. (n = microprocessor
number)
81010002-0701ffff
Numeric sensor
[NumericSensorElementName] going
low (lower non-critical) has deasserted.
(CMOS Battery)
Explanation: This message is for the use case when an
implementation has detected a Lower Non-critical
sensor going low has deasserted.
May also be shown as 810100020701ffff or
0x810100020701ffff
Severity: Info
Alert Category: Warning - Voltage
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0477
SNMP Trap ID: 13
Automatically notify Support: No
454
System x3550 M4 Type 7914: Installation and Service Guide
User response: No action; information only.
81010202-0701ffff
Numeric sensor
[NumericSensorElementName] going
low (lower critical) has deasserted.
(CMOS Battery)
Explanation: This message is for the use case when an
implementation has detected a Lower Critical sensor
going low has deasserted.
May also be shown as 810102020701ffff or
0x810102020701ffff
Severity: Info
Alert Category: Critical - Voltage
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0481
SNMP Trap ID: 1
Automatically notify Support: No
User response: No action; information only. SysBrd
12V : SysBrd 3.3V : SysBrd 5V :
81010204-1d01ffff
Numeric sensor
[NumericSensorElementName] going
low (lower critical) has deasserted. (Fan
1A Tach)
Explanation: This message is for the use case when an
implementation has detected a Lower Critical sensor
going low has deasserted.
May also be shown as 810102041d01ffff or
0x810102041d01ffff
Severity: Info
Alert Category: Critical - Fan Failure
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0481
SNMP Trap ID: 11
Automatically notify Support: No
User response: No action; information only. Fan 1B
Tach :
81010204-1d02ffff
Numeric sensor
[NumericSensorElementName] going
low (lower critical) has deasserted. (Fan
2A Tach)
Explanation: This message is for the use case when an
implementation has detected a Lower Critical sensor
going low has deasserted.
May also be shown as 810102041d02ffff or
0x810102041d02ffff
Severity: Info