80010b01-2d01ffff
Numeric sensor
[NumericSensorElementName] going
high (upper non-recoverable) has
asserted. (PCH Temp)
Explanation: This message is for the use case when an
implementation has detected an Upper Non-recoverable
sensor going high has asserted.
May also be shown as 80010b012d01ffff or
0x80010b012d01ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response: Check the server airflow. Make sure
that nothing is blocking the air from coming into or
preventing the air from exiting the server.
80030006-2101ffff
Sensor [SensorElementName] has
deasserted. (Sig Verify Fail)
Explanation: This message is for the use case when an
implementation has detected a Sensor has deasserted.
May also be shown as 800300062101ffff or
0x800300062101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0509
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
80030012-2301ffff
Sensor [SensorElementName] has
deasserted. (OS RealTime Mod)
Explanation: This message is for the use case when an
implementation has detected a Sensor has deasserted.
May also be shown as 800300122301ffff or
0x800300122301ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0509
SNMP Trap ID:
Automatically notify Support: No
80010b01-2d01ffff • 8007010f-2201ffff
User response: No action; information only.
80030108-1301ffff
Explanation: This message is for the use case when an
implementation has detected a Sensor has asserted.
May also be shown as 800301081301ffff or
0x800301081301ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0508
SNMP Trap ID:
Automatically notify Support: No
User response:
Replace the power supply with higher rated power.
1.
2.
Reduce the total power consumption by removing
newly added or unused option like drives or
adapters.
80070101-0c01ffff
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
non-critical from normal.
May also be shown as 800701010c01ffff or
0x800701010c01ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1.
Check the microprocessor installed is Intel E5-2690.
2.
Reduce the ambient temperature under 27 Celsius
degree.
8007010f-2201ffff
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
non-critical from normal.
May also be shown as 8007010f2201ffff or
0x8007010f2201ffff
Appendix A. Integrated management module II (IMM2) error messages
Sensor [SensorElementName] has
asserted. (PS Heavy Load)
Sensor [SensorElementName] has
transitioned from normal to non-critical
state. (Ambient Status)
Sensor [SensorElementName] has
transitioned from normal to non-critical
state. (GPT Status)