Lenovo x3550 M4 Installation And Service Manual page 459

Hide thumbs Also See for x3550 M4:
Table of Contents

Advertisement

SNMP Trap ID: 50
Automatically notify Support: Yes
User response:
1.
Check the system-event log.
2.
Check the DIMM error LEDs.
3.
Remove the failing DIMM from the system board.
4.
Check for a server firmware update. Important:
Some cluster solutions require specific code levels
or coordinated code updates. If the device is part of
a cluster solution, verify that the latest level of code
is supported for the cluster solution before you
update the code.
5.
Make sure that the installed DIMMs are supported
and configured correctly.
6.
(Trained technician only) Replace the system board.
806f0813-2582ffff
A Uncorrectable Bus Error has
occurred on system
[ComputerSystemElementName]. (PCIs)
Explanation: This message is for the use case when an
implementation has detected a Bus Uncorrectable Error.
May also be shown as 806f08132582ffff or
0x806f08132582ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0240
SNMP Trap ID: 50
Automatically notify Support: Yes
User response:
1.
Check the system-event log.
2.
Check the PCI LED.
3.
Remove the adapter from the indicated PCI slot.
Check for a server firmware update. Important:
4.
Some cluster solutions require specific code levels
or coordinated code updates. If the device is part of
a cluster solution, verify that the latest level of code
is supported for the cluster solution before you
update the code.
5.
(Trained technician only) Replace the system board.
806f0813-2584ffff
A Uncorrectable Bus Error has
occurred on system
[ComputerSystemElementName]. (CPUs)
Explanation: This message is for the use case when an
implementation has detected a Bus Uncorrectable Error.
May also be shown as 806f08132584ffff or
0x806f08132584ffff
Severity: Error
806f0813-2582ffff • 806f090c-2001ffff
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0240
SNMP Trap ID: 50
Automatically notify Support: Yes
User response:
Check the system-event log.
1.
2.
(Trained technician only) Remove the failing
microprocessor from the system board (see
Removing a microprocessor and heat sink).
Check for a server firmware update. Important:
3.
Some cluster solutions require specific code levels
or coordinated code updates. If the device is part of
a cluster solution, verify that the latest level of code
is supported for the cluster solution before you
update the code.
4.
Make sure that the two microprocessors are
matching.
5.
(Trained technician only) Replace the system board.
806f0823-2101ffff
Explanation: This message is for the use case when an
implementation has detected a Watchdog Timer
interrupt occurred.
May also be shown as 806f08232101ffff or
0x806f08232101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0376
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f090c-2001ffff
Explanation: This message is for the use case when an
implementation has detected Memory has been
Throttled.
May also be shown as 806f090c2001ffff or
0x806f090c2001ffff
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
Appendix A. Integrated management module II (IMM2) error messages
Watchdog Timer interrupt occurred
for [WatchdogElementName]. (IPMI
Watchdog)
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName]
Throttled. (DIMM 1)
441

Advertisement

Table of Contents
loading

Table of Contents