Lenovo x3550 M4 Installation And Service Manual page 272

Hide thumbs Also See for x3550 M4:
Table of Contents

Advertisement

Replacing the dual-port network adapter
You can purchase one of the following dual-port network adapters to add two
additional network ports in the server.
About this task
To order a dual-port network adapter option, contact your sales representative or
reseller.
The following notes describe the types of adapters that the server supports and
other information that you must consider when you install an adapter:
v To configure network adapters, complete the following steps:
v To convert the NIC/iSCSI/FCoE for Emulex Dual Port 10GbE SFP+ Embedded
254
System x3550 M4 Type 7914: Installation and Service Guide
Table 27. Supported dual-port network adapters on the network connector
Dual-port network adapter
Mellanox ConnectX-3 dual-port
QDR/FDR10 mezz card
Qlogic dual-port 10GbE SFP+
Embedded VFA
Emulex dual-port 10GbE SFP+
Embedded VFA III
Dual-port FDR embedded adapter
Broadcom dual port 10GbE SFP+
embedded adapter for System x
Table note:
1. You can purchase System x3550 M4 Thermal Solution Kit (option part number 00Y7117)
to acquire two additional fans for your server.
1. From the Setup utility main menu (see "Using the Setup utility" on page
102), select System Settings > Network.
2. From the Network Device List, select one network adapter.
Note: You might need to enter each item (displaying MAC address) to see
detailed information.
3. Press Enter to configure the network adapter settings.
VFA III, complete the following steps:
1. From the Setup utility main menu (see "Using the Setup utility" on page
102), select System Settings > Network and press Enter.
2. From the Network Device List, select Emulex network adapter.
Note: You might need to enter each item (displaying MAC address) to see
detailed information.
3. Press Enter to configure Emulex network adapter, select Personality and
press Enter to change the settings.
– NIC
– iSCSI (enabled after FoD installed)
– FCoE (enabled after FoD installed)
Option
part
FRU part
number
number
Remark
90Y6338
90Y4956
90Y6454
90Y5099
Six fans installed
required
90Y6456
90Y5100
00D4143
90Y6606
44T1360
00AL195
Six fans installed
required
1