Alert Category: Critical - Hard Disk drive
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0162
SNMP Trap ID: 5
Automatically notify Support: No
User response: No action; information only.
806f000f-220101ff
The System
[ComputerSystemElementName] has
detected no memory in the system.
(ABR Status)
Explanation: This message is for the use case when an
implementation has detected that memory was detected
in the system.
May also be shown as 806f000f220101ff or
0x806f000f220101ff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0794
SNMP Trap ID: 41
Automatically notify Support: No
User response:
1.
Make sure the server meets the minimum
configuration to start (see Power-supply LEDs).
2.
Recover the server firmware from the backup page:
a. Restart the server. b. At the prompt, press F3 to
recover the firmware.
Update the server firmware on the primary page.
3.
Important: Some cluster solutions require specific
code levels or coordinated code updates. If the
device is part of a cluster solution, verify that the
latest level of code is supported for the cluster
solution before you update the code.
4.
Remove components one at a time, restarting the
server each time, to see if the problem goes away.
5.
If the problem remains, (trained technician only)
replace the system board.
Firmware Error : Sys Boot Status :
806f000f-220102ff
Subsystem
[MemoryElementName] has insufficient
memory for operation. (ABR Status)
Explanation: This message is for the use case when an
implementation has detected that the usable Memory is
insufficient for operation.
May also be shown as 806f000f220102ff or
0x806f000f220102ff
806f000f-220101ff • 806f000f-220104ff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0132
SNMP Trap ID: 41
Automatically notify Support: No
User response:
1.
Make sure the server meets the minimum
configuration to start (see Power-supply LEDs).
2.
Update the server firmware on the primary page.
Important: Some cluster solutions require specific
code levels or coordinated code updates. If the
device is part of a cluster solution, verify that the
latest level of code is supported for the cluster
solution before you update the code.
(Trained technician only) Replace the system board.
3.
Firmware Error : Sys Boot Status :
806f000f-220103ff
Explanation: This message is for the use case when an
implementation has detected that System Firmware
Error Unrecoverable boot device failure has occurred.
May also be shown as 806f000f220103ff or
0x806f000f220103ff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0770
SNMP Trap ID: 5
Automatically notify Support: No
User response: This is a UEFI detected event. The
UEFI(POST) error code for this event can be found in
the logged IMM message text. Please refer to the
UEFI(POST) error code in the "UEFI(POST) error code"
section of the Information Center for the appropriate
user response. Firmware Error : Sys Boot Status :
806f000f-220104ff
Explanation: This message is for the use case when an
implementation has detected that a fatal motherboard
failure in the system.
Appendix A. Integrated management module II (IMM2) error messages
The System
[ComputerSystemElementName]
encountered firmware error -
unrecoverable boot device failure. (ABR
Status)
The System
[ComputerSystemElementName]has
encountered a motherboard failure.
(ABR Status)