I.3818003
[I.3818003] The CRTM flash driver could
not lock the secure flash region.
Explanation: CRTM Could not lock secure flash region
Severity: Info
User response: Complete the following steps:
If system failed to boot successfully, DC cycle
1.
system.
If system boots to F1 setup, flash UEFI image and
2.
reset bank to primary (if required). If system boots
without error, recovery is complete and no
additional action is required.
If system fails to boot, or if flash attempt fails,
3.
(Trained service technician only) Replace the system
board.
I.58015
[I.58015] Memory spare copy initiated.
Explanation: Spare Copy Started
Severity: Info
User response: Complete the following steps:
No user required for this event. This is for
1.
informational purposes only.
I.580A4
[I.580A4] Memory population change
detected.
Explanation: DIMM Population Change Detected
Severity: Info
User response: Complete the following steps:
1.
Check system event log for uncorrected DIMM
failures and replace those DIMMs.
I.580A5
[I.580A5] Mirror Fail-over complete.
DIMM number % has failed over to to
the mirrored copy.
Explanation: DIMM Mirror Fail-over Detected
Severity: Info
User response: Complete the following steps:
1.
Check the system-event log for uncorrected DIMM
failures and replace those DIMMs.
I.580A6
[I.580A6] Memory spare copy has
completed successfully.
Explanation: Spare Copy Complete
Severity: Info
User response: Complete the following steps:
1.
Check system log for related DIMM failures and
replace those DIMMs.
S.1100B
[S.1100B] CATERR(IERR) has asserted
on processor %.
Explanation: Processor CATERR(IERR) has asserted
Severity: Error
User response: Complete the following steps:
Check IBM support site for an applicable service
1.
bulletin or firmware update that applies to this
Processor error.
(Trained Service technician only) Replace the
2.
Processor.
S.1100C
[S.1100C] An uncorrectable error has
been detected on processor %.
Explanation: Uncorrectable processor error detected
Severity: Error
User response: Complete the following steps:
Check IBM support site for an applicable service
1.
bulletin or firmware update that applies to this
error.
Reboot system. If problem persists escalate to the
2.
next level of supprt.
S.2011001
[S.2011001] An Uncorrected PCIe Error
has Occurred at Bus % Device %
Function %. The Vendor ID for the
device is % and the Device ID is %.
Explanation: PCI SERR Detected
Severity: Error
User response: Complete the following steps:
1.
If this node and/or any attached cables were
recently installed, moved, serviced or upgraded, a.
Reseat Adapter and any attached cables. b. Reload
Device Driver c. If device is not recognized,
reconfiguring slot to Gen1 or Gen2 may be required.
Gen1/Gen2 settings can be configured via F1 Setup
-> System Settings -> Devices and I/O Ports ->
PCIe Gen1/Gen2/Gen3 Speed Selection, or the ASU
Utility.
2.
Check IBM support site for an applicable device
driver, firmware update, revision of service
information for this product or other information
that applies to this error. Load new device driver
and any required firmware updates.
If problem persists, then remove Adapter Card. If
3.
system reboots successfully without the adapter,
replace that card.
(Trained Service technician only) Replace the
4.
processor.
Appendix B. UEFI/POST diagnostic codes