3. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reseat DIMM(s). Reconnect it
to power.
4. Make sure that DSA and BIOS/uEFI are at the latest
level.
5. Replace any DIMMS(s) mentioned in error, one by
one.
6. Make sure that all DIMMs are enabled in the
Configuration/Setup Utility program.
7. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
201-901-003
Standalone Memory Test Failed
Explanation: Memory Diagnostics Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No

DSA memory stress test results

The following messages can result when you run the memory stress test.
202-000-000
MemStr Test Passed
Explanation: Test Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
202-801-000
MemStr Test Aborted
Explanation: Internal program error.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Turn off and restart the system.
201-901-003 • 202-802-000
Automatically notify Support: No
User response: Complete the following steps:
1. Perform the actions mentioned one at a time and
try the test after each action.
2. If the problem remains, contact your
technical-service representative.
3. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reseat DIMM(s). Reconnect it
to power.
4. Make sure that DSA and BIOS/uEFI are at the latest
level.
5. Replace any DIMMS(s) mentioned in error, one by
one.
6. Make sure that all DIMMs are enabled in the
Configuration/Setup Utility program.
7. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
2. Make sure that the DSA Diagnostic code is at the
latest level.
3. Run the test again.
4. If the system has stopped responding, turn off and
restart the system.
5. Check the system firmware level and upgrade if
necessary.
6. Run the memory diagnostic to identify the specific
failing DIMM.
7. If the failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related Links:
IBM Support Website
v
Latest level of DSA
v
v
Latest level of BMC/IMM
202-802-000
MemStr Test Aborted
Explanation: Memory size is insufficient to run the
test. At least 1 GB is required.
Severity: Warning
Serviceable: Yes
Recoverable: No
Appendix C. DSA diagnostic test results