Lenovo x3550 M4 Installation And Service Manual page 397

Hide thumbs Also See for x3550 M4:
Table of Contents

Advertisement

May also be shown as 806f000f22010cff or
0x806f000f22010cff
Severity: Error
Alert Category: Critical - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0050
SNMP Trap ID: 40
Automatically notify Support: No
User response: This is a UEFI detected event. The
UEFI(POST) error code for this event can be found in
the logged IMM message text. Please refer to the
UEFI(POST) error code in the "UEFI(POST) error code"
section of the Info Center for the appropriate user
response. Firmware Error : Sys Boot Status :
806f000f-2201ffff
The System
[ComputerSystemElementName]
encountered a POST Error. (ABR Status)
Explanation: This message is for the use case when an
implementation has detected a Post Error.
May also be shown as 806f000f2201ffff or
0x806f000f2201ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0184
SNMP Trap ID: 50
Automatically notify Support: No
User response: This is a UEFI detected event. The
UEFI(POST) error code for this event can be found in
the logged IMM message text. Please refer to the
UEFI(POST) error code in the "UEFI(POST) error code"
section of the Information Center for the appropriate
user response. Firmware Error : Sys Boot Status :
806f0013-1701ffff
A diagnostic interrupt has occurred
on system
[ComputerSystemElementName]. (NMI
State)
Explanation: This message is for the use case when an
implementation has detected a Front Panel NMI /
Diagnostic Interrupt.
May also be shown as 806f00131701ffff or
0x806f00131701ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0222
806f000f-2201ffff • 806f0021-2582ffff
SNMP Trap ID: 50
Automatically notify Support: No
User response: If the NMI button has not been
pressed, complete the following steps:
1.
Make sure that the NMI button is not pressed.
2.
Replace the operator information panel cable.
3.
Replace the operator information panel.
806f0021-2201ffff
Explanation: This message is for the use case when an
implementation has detected a Fault in a slot.
May also be shown as 806f00212201ffff or
0x806f00212201ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0330
SNMP Trap ID: 50
Automatically notify Support: Yes
User response:
1.
Check the PCI LED.
2.
Reseat the affected adapters and riser card.
3.
Update the server firmware (UEFI and IMM) and
adapter firmware. Important: Some cluster solutions
require specific code levels or coordinated code
updates. If the device is part of a cluster solution,
verify that the latest level of code is supported for
the cluster solution before you update the code.
4.
Remove both adapters.
5.
Replace the riser card.
6.
(Trained service technicians only) Replace the
system board.
806f0021-2582ffff
Explanation: This message is for the use case when an
implementation has detected a Fault in a slot.
May also be shown as 806f00212582ffff or
0x806f00212582ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
Appendix A. Integrated management module II (IMM2) error messages
Fault in slot
[PhysicalConnectorSystemElementName]
on system
[ComputerSystemElementName]. (No
Op ROM Space)
Fault in slot
[PhysicalConnectorSystemElementName]
on system
[ComputerSystemElementName]. (All
PCI Error)
379

Advertisement

Table of Contents
loading

Table of Contents