[S.2018001] An Uncorrected PCIe Error
has Occurred at Bus % Device %
Function %. The Vendor ID for the
device is % and the Device ID is %.
Explanation: PCIe Uncorrected Error Detected
Severity: Error
User response: Complete the following steps:
If this node and/or any attached cables were
1.
recently installed, moved, serviced or upgraded, a.
Reseat Adapter and any attached cables. b. Reload
Device Driver c. If device is not recognized,
reconfiguring slot to Gen1 or Gen2 may be required.
Gen1/Gen2 settings can be configured via F1 Setup
-> System Settings -> Devices and I/O Ports ->
PCIe Gen1/Gen2/Gen3 Speed Selection, or the ASU
Utility.
2.
Check IBM support site for an applicable device
driver, firmware update, version of service
information for this product or other information
that applies to this error. Load new device driver
and any required firmware updates.
3.
If problem persists, then remove Adapter Card. If
system reboots successfully without the adapter,
replace that card.
4.
Trained Service technician only) Replace the
processor.
S.3020007
[S.3020007] A firmware fault has been
detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected,
System halted
Severity: Error
User response: Complete the following steps:
Check IBM support site for an applicable service
1.
bulletin or firmware update that applies to this
error.
Reflash UEFI image.
2.
3.
(Trained service technician only) Replace the
system board.
S.3028002
[S.3028002] Boot permission timeout
detected.
Explanation: Boot Permission Negotiation Timeout
Severity: Error
User response: Complete the following steps:
Check CMM/IMM logs for communication errors
1.
and resolve.
Reseat system
2.
3.
If problem persists escalate to the next level of
support
524
System x3550 M4 Type 7914: Installation and Service Guide
S.3030007
[S.3030007] A firmware fault has been
detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected,
System halted
Severity: Error
User response: Complete the following steps:
Check IBM support site for an applicable service
1.
bulletin or firmware update that applies to this
error.
Reflash UEFI image.
2.
(Trained service technician only) Replace the
3.
system board.
S.3040007
[S.3040007] A firmware fault has been
detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected,
System halted
Severity: Error
User response: Complete the following steps:
Check IBM support site for an applicable service
1.
bulletin or firmware update that applies to this
error.
2.
Reflash UEFI image.
(Trained service technician only) Replace the
3.
system board.
S.3050007
[S.3050007] A firmware fault has been
detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected,
System halted
Severity: Error
User response: Complete the following steps:
1.
Check IBM support site for an applicable service
bulletin or firmware update that applies to this
error.
2.
Reflash UEFI image.
3.
(Trained service technician only) Replace the
system board.
S.3058004
[S.3058004] A Three Strike boot failure
has occurred. The system has booted
with default UEFI settings.
Explanation: POST failure has occurred! System
booted with default settings.
Severity: Error
User response: Complete the following steps:
1.
This event resets UEFI to the default settings for
the next boot. If successful, user is forced into F1
setup. Original UEFI settings are still present.