Lenovo x3550 M4 Installation And Service Manual page 385

Hide thumbs Also See for x3550 M4:
Table of Contents

Advertisement

SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow (front and rear of
the server), that the air baffles are in place and
correctly installed, and that the server cover is
installed and completely closed.
Check the ambient temperature. You must be
2.
operating within the specifications (see Features and
specifications for more information).
Make sure that the heat sink for microprocessor n
3.
is installed correctly.
(Trained technician only) Replace microprocessor n.
4.
(n = microprocessor number)
80070202-0701ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (SysBrd Vol Fault)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 800702020701ffff or
0x800702020701ffff
Severity: Error
Alert Category: Critical - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 1
Automatically notify Support: No
User response:
1.
Check the system-event log.
2.
Check for an error LED on the system board.
3.
Replace any failing device.
4.
Check for a server firmware update. Important:
Some cluster solutions require specific code levels
or coordinated code updates. If the device is part of
a cluster solution, verify that the latest level of code
is supported for the cluster solution before you
update the code.
5.
(Trained technician only) Replace the system board.
80070204-0a01ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (PS 1 Fan Fault)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 800702040a01ffff or
0x800702040a01ffff
80070202-0701ffff • 80070208-0a01ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Make sure that there are no obstructions, such as
bundled cables, to the airflow from the
power-supply fan.
2.
Replace power supply n. (n = power supply
number)
80070204-0a02ffff
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 800702040a02ffff or
0x800702040a02ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Make sure that there are no obstructions, such as
bundled cables, to the airflow from the
power-supply fan.
2.
Replace power supply n. (n = power supply
number)
80070208-0a01ffff
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 800702080a01ffff or
0x800702080a01ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 4
Appendix A. Integrated management module II (IMM2) error messages
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (PS 2 Fan Fault)
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (PS 1 Therm Fault)