Lenovo x3550 M4 Installation And Service Manual page 384

Hide thumbs Also See for x3550 M4:
Table of Contents

Advertisement

8007010f-2582ffff • 80070201-0302ffff
Severity: Warning
Alert Category: Warning - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 60
Automatically notify Support: No
User response:
1.
Check the IBM support site for service bulletins or
firmware updates that apply to this GPT error.
2.
Set the UEFI setting DISK GPT Recovery to
Automatic.
3.
Replace the corrupt disk.
8007010f-2582ffff
Sensor [SensorElementName] has
transitioned from normal to non-critical
state. (I/O Resources)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
non-critical from normal.
May also be shown as 8007010f2582ffff or
0x8007010f2582ffff
Severity: Warning
Alert Category: Warning - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 60
Automatically notify Support: No
User response: Complete the following step to solve
PCI I/O resource errors:
1.
Go to F1 Setup-> System Settings-> Device and
I/O ports-> PCI 64 bit Resource and choose enable.
80070114-2201ffff
Sensor [SensorElementName] has
transitioned from normal to non-critical
state. (TPM Phy Pres Set)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
non-critical from normal.
May also be shown as 800701142201ffff or
0x800701142201ffff
Severity: Warning
Alert Category: Warning - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 60
Automatically notify Support: No
366
System x3550 M4 Type 7914: Installation and Service Guide
User response:
1.
Complete the administrative tasks that require the
TPM physical presence switch to be in the ON
position.
2.
Restore the physical presence switch to the OFF
position.
3.
Reboot the system.
4.
(Trained technician only) If the error continues,
replace the planar.
80070201-0301ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (CPU 1 OverTemp)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 800702010301ffff or
0x800702010301ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 0
Automatically notify Support: No
User response:
Make sure that the fans are operating, that there
1.
are no obstructions to the airflow (front and rear of
the server), that the air baffles are in place and
correctly installed, and that the server cover is
installed and completely closed.
2.
Check the ambient temperature. You must be
operating within the specifications (see Features and
specifications for more information).
3.
Make sure that the heat sink for microprocessor n
is installed correctly.
4.
(Trained technician only) Replace microprocessor n.
(n = microprocessor number)
80070201-0302ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (CPU 2 OverTemp)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 800702010302ffff or
0x800702010302ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522

Advertisement

Table of Contents
loading

Table of Contents