5
Maintenance
Follow the simple procedures within this chapter to ensure continued proper operation of the
printer.
Startup Kit Tools
The Startup Kit contains replacement parts and a set of tools used to help you maintain the system.
The following is a list of the tools contained in the Startup Kit.
•
Needle Nose Pliers
•
T-Handled Wrench -
•
T-Handled Wrench -
•
Leather Insulated Gloves (Pair)
•
Cutters
•
Brush (bronze)
•
Magnifier
Preventive Maintenance
Daily
Inspect the tip wipe assembly
After each build you should inspect the tip wipe assembly to make sure there is no material build up
or wear. If there is material build up or wear, clean the tip wipe assembly. Material build up on the
tip wipe assembly can cause part quality issues. See
Inspect the tip shrouds
After each build you should inspect the tip shrouds for damage or material build up. If there is
material build up remove it as needed. If the material will not break free or there is damage to the
tip shield, replace the tip shield. See
Remove debris buildup
Remove all material buildup on the Z platform and around the lead screw. Failure to do so could
cause the base to not be level or the Z platform to jam at its upper limit.
Vacuum build chamber
Vacuum the build chamber to remove all debris and purged material.
1
⁄
"
8
7
⁄
"
64
"Tip shield replacement" on page 40.
35
"Replace the tip wipe assembly" on page 38.