Quick Steps for Setting Up An SNMP Management Station
Quick Steps for Setting Up An SNMP
Management Station
An SNMP Network Management Station (NMS) is a workstation configured to receive SNMP traps from
the switch. To set up an SNMP NMS by using the switch's CLI, proceed as follows:
1 Specify the user account name and the authentication type for that user. For example:
-> user NMSuserV3MD5DES md5+des password ********
2 Specify the UDP destination port number (in this case 8010), the IP address of the management station
(199.199.100.200), a user account name (NMSuserV3MD5DES), and the SNMP version number (v3). For
example:
-> snmp station 199.199.100.200 8010 NMSuserV3MD5DES v3 enable
Use the same command as above for specifying the IPv6 address of the management station. For example:
-> snmp station 300::1 enable
Note. Optional. To verify the SNMP Management Station, enter the
display is similar to the one shown here:
-> show snmp station
ipAddress/udpPort
---------------------------+---------+--------+-------------------------------
199.199.100.200/8010
199.199.101.201/111
199.199.102.202/8002
-> show snmp station
ipAddress/udpPort
---------------------------------------------------+---------+--------+------
172.21.160.32/4000
172.21.160.12/5000
0300:0000:0000:0000:0211:d8ff:fe47:470b/4001
0300:0000:0000:0000:0211:d8ff:fe47:470c/5001
For more information about this display, see the "SNMP Commands" chapter in the OmniSwitch 6250/
6450 CLI Reference Guide.
page 3-4
status
protocol user
enable
v3
NMSuserV3MD5DES
disable
v2
NMSuserV3MD5
enable
v1
NMSuserV3SHADES
OmniSwitch 6250/6450 Switch Management Guide
show snmp station
command. The
status
protocol user
enable
v3
abc
enable
v3
user1
enable
v3
user2
enable
v2
abc
Using SNMP
June 2013