SNMP Traps Table
No. Trap Name
164 alaTestOamRxReadyTrap
alaTestOamConfigTestId—A unique name to identify the entries in the table.
alaTestOamConfigSourceEndpoint—The the local or transmitting switch. For bidirectional test, this also iden-
tifies the analyzer switch.
alaTestOamConfigTestIdStatus—The test status (not started, running, stopped, ended).
165 alaTestOamTestAbortTrap
alaTestOamConfigTestId—A unique name to identify the entries in the table.
166 Reserved
167 Reserved
168 alaSaaIPIterationCompleteTrap
alaSaaCtrlOwnerIndex—An owner name to identify entries in the table. This is currently not supported and its
value will always be the string 'USER'.
alaSaaCtrlTestIndex—A unique name to identify the entries in the table. The name is unique across various
SNMP users.
alaSaaIpResultsTestRunIndex—Identifies the row entry that reports results for a single OAM test run. The
value of this object starts from 1 and can go upto a maximum of alaSaaCtrlMaxHistoryRows.
alaSaaCtrlLastRunResult—The result of the latest SAA test iteration: 1 - Undetermined, 2 - Success, 3 -
Failed, 4 - Aborted.
alaSaaCtrlLastRunTime—The date and time at which the last iteration of the SAA was run.
169 alaSaaEthIterationCompleteTrap
page B-26
Objects
Family
alaTestOamCon-
bridge
figTestId,
alaTestOamCon-
figSourceEnd-
point,
alaTestOamCon-
figTestIdStatus
alaTestOamCon-
bridge
figTestId
alaSaaCtrlOwn-
system
erIndex,
alaSaaCtrlT-
estIndex,
alaSaaIpResult-
sTestRunIn-
dex,
alaSaaCtrlLas-
tRunResult,
alaSaaCtrlLas-
tRunTime
alaSaaCtrlOwn-
system
erIndex,
alaSaaCtrlT-
estIndex,
alaSaaEthoam-
ResultsT-
estRunIndex,
alaSaaCtrlLas-
tRunResult,
alaSaaCtrlLas-
tRunTime
OmniSwitch 6250/6450 Switch Management Guide
SNMP Trap Information
Description
This trap is sent to the NMS once
the switch with Analyzer or
Loopback Role is ready to
receive test traffic. Once this trap
is received, the Generator is acti-
vated for generating test traffic.
This trap is sent to the NMS from
the switch, if the test is aborted
during takeover.
This trap is sent when an IP SAA
iteration is completed.
This trap is sent is sent when a
Eth-LB or Eth-DMM SAA itera-
tion is completed.