Alcatel-Lucent OmniSwitch 6450 Management Manual page 351

Hide thumbs Also See for OmniSwitch 6450:
Table of Contents

Advertisement

SNMP Trap Information
No. Trap Name
dot3OamEventLogTimestamp—The sysUpTime at the time of the logged event.
dot3OamEventLogOui—The OUI of the entity defining the object type. All IEEE 802.3 defined events (as
appearing in [802.3ah] except for the Organizationally Unique Event TLVs) use the IEEE 802.3 OUI of
0x0180C2. Organizations defining their own Event Notification TLVs include their OUI in the Event Notifica-
tion TLV that is reflected here.
dot3OamEventLogType—The type of event that generated this entry in the event log. When the OUI is the
IEEE 802.3 OUI of 0x0180C2, the following event types are defined: erroredSymbolEvent(1), erroredFramePe-
riodEvent(2), erroredFrameEvent(3), erroredFrameSecondsEvent(4), linkFault(256), dyingGaspEvent(257),
criticalLinkEvent(258).
dot3OamEventLogLocation—Indicates whether this event occurred locally (local(1)), or was received from
the OAM peer via Ethernet OAM (remote(2)).
dot3OamEventLogWindowHi—The time interval, in seconds, that is used to monitor the "High" threshold
limit for this event. A notification is sent every time the threshold is exceeded during any 5-second monitoring
interval.
dot3OamEventLogWindowLo—The time interval, in seconds, that is used to monitor the "Low" threshold
limit for this event. A notification is sent every time the threshold is exceeded during any 5-second monitoring
interval.
dot3OamEventLogThresholdHi—The "High" threshold level set for the event.
dot3OamEventLogThresholdLo—The "Low" threshold level set for the event.
dot3OamEventLogValue—The value of the event when it exceeded a threshold limit.
dot3OamEventLogRunningTotal—the total number of times this event has happened since the last reset
dot3OamEventLogEventTotal—The total number of times this event has resulted in a notification.
122 alaDot3OamNonThresholdEventClear dot3OamEventL
dot3OamEventLogTimestamp—The value of sysUpTime at the time of the logged event.
dot3OamEventLogOui—The OUI of the entity defining the object type. All IEEE 802.3 defined events (as
appearing in [802.3ah] except for the Organizationally Unique Event TLVs) use the IEEE 802.3 OUI of
0x0180C2. Organizations defining their own Event Notification TLVs include their OUI in the Event Notifica-
tion TLV that gets reflected here.
dot3OamEventLogType—The type of event that generated this entry in the event log. When the OUI is the
IEEE 802.3 OUI of 0x0180C2, the following event types are defined: erroredSymbolEvent(1), erroredFramePe-
riodEvent(2), erroredFrameEvent(3), erroredFrameSecondsEvent(4), linkFault(256), dyingGaspEvent(257),
criticalLinkEvent(258).
dot3OamEventLogLocation—Indicates whether this event occurred locally (local(1)), or was received from
the OAM peer via Ethernet OAM (remote(2)).
dot3OamEventLogEventTotal—The total number of times this event has resulted in a notification.
123
Reserved
-
146
OmniSwitch 6250/6450 Switch Management Guide
Objects
Family
dot3-oam
ogTimestamp
dot3OamEventL
ogOui
dot3OamEventL
ogType
dot3OamEventL
ogLocation
dot3OamEventL
ogEventTotal
June 2013
SNMP Traps Table
Description
This trap is sent is sent when a
local or remote non-threshold
crossing event is recovered.
page B-23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omniswitch 6350Omniswitch 6250

Table of Contents