Special, Non-Latched - EWM PHOENIX 301 EXPERT forceArc Operating Instructions Manual

Machines for mig/mag, tig and mma welding
Table of Contents

Advertisement

Functional characteristics
MIG/MAG welding
5.2.5.4

Special, non-latched

I
Step 1
Press and hold torch trigger
Shielding gas is expelled (gas pre-flows)
Wire feed motor runs at "creep speed".
Arc ignites after the wire electrode makes contact with the workpiece, welding current is flowing (start
program P
START
Slope to main program P
Step 2
Release torch trigger
Slope to end program P
WF motor stops.
Arc is extinguished after the preselected wire burn-back time expires.
Gas post-flow time elapses.
44
1.
P
START
for the time t
)
start
.
A
for the time t
END
P
A
Figure 5-10
.
end
2.
t
P
END
t
t
Item No.: 099-004833-EWM01

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PHOENIX 301 EXPERT forceArc and is the answer not in the manual?

Questions and answers

Table of Contents