L1 Controller Error Messages - Silicon Graphics Prism Hardware User's Manual

Visualization system deskside
Hide thumbs Also See for Prism:
Table of Contents

Advertisement

L1 Controller Error Messages

007-4772-002
Table 4-1
Troubleshooting Chart (continued)
Problem Description
The red service-required LED
illuminates.
The PWR LED of a populated PCI slot is
not illuminated.
The fault LED of a populated PCI slot is
illuminated.
The amber LED of a disk drive is
illuminated.
Table 4-2 lists error messages that the L1 controller generates and displays on the L1
display. This display is located on the front of the deskside system. For serial number
related errors, check with your service provider for documentation on prevention and
solutions.
The serial number error messages listed at the end of Table 4-2 can come across the L1
console from the L1 log. Obtain the contents by using the log command from an L1
prompt.
Actions that could cause serial number error messages include:
Replacing the interface board of a system.
L1 NVRAM memory failure.
Recommended Action
View the L1 display of the failing system; see
Table 4-2 for a description of the error message.
Reseat the PCI card and reboot the system.
Reseat the PCI card and reboot the system. If the fault
LED remains on, replace the PCI card.
Replace the disk drive.
General Troubleshooting