ENGINE OIL
OIL LEVEL CHECK
Place the motorcycle on the centre stand
Before checking the oil level start and warm
the engine for few minutes. Switch "OFF"
the ignition, wait for two minutes and then
check oil level at the inspection window on
the RH Crankcase cover
Two level marks are provided on the
Oil level window in Cover RH Max. & Min.
If oil level is below the Min mark top up, till
the level in between Max and Min mark. Do
not overfill.
NOTE :
Oil capacity Min to Max mark is approx
350 ml.
Max
Min
OIL CHANGE :
Refer Periodical Maintenance chart
(page No. 03-10) for frequency.
Keep vehicle on level ground.
Start the engine and warm up sufficiently
so that the oil drains faster.
DRAINING PROCEDURE :
Keep a clean tray under the engine
Remove the two Hex Flange Bolts M5 X 16,
Sump drain Cap, "O" ring and Suction filter
Assy.
Remove the Magnetic Plug assy along with
its washer.
TILT VEHICLE RH & LH
After the oil drains out, remove vehicle from
centre stand and tilt the vehicle to both LH
and RH sides 3 to 4 times to drain out
maximum oil.
Quantity of oil that can be drained in 2.35
Litres approximately.
Tighten the oil drain bolt with washer.
Assemble the cleaned suction filter element
in to Crank case and fix drain cap with
"O"ring.
Fill up with 15W50 API SL grade.
Refil oil quantity 2.40 Litres approximately.